Silicon Labs /SiM3_NRND /SIM3L166_C /ACCTR_0 /CONTROL

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as CONTROL

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (32_PERCENT)CMPLTH 0 (48_PERCENT)CMPHTH 0 (UNTIL_PASS)CALMD 0 (FULL)CALPUMD 0 (DISABLED)FPUPEN 0 (DISABLED)FPDNEN 0PUVAL0 (IN0)CALSEL 0 (NOT_SET)CALRF 0 (NOT_SET)CALBUSYF

CALRF=NOT_SET, FPDNEN=DISABLED, FPUPEN=DISABLED, CALPUMD=FULL, CALSEL=IN0, CALBUSYF=NOT_SET, CMPHTH=48_PERCENT, CMPLTH=32_PERCENT, CALMD=UNTIL_PASS

Description

Control Register

Fields

CMPLTH

Comparator Low Threshold.

0 (32_PERCENT): Set the digital comparator low threshold to 32% of VIO.

1 (36_PERCENT): Set the digital comparator low threshold to 36% of VIO.

2 (40_PERCENT): Set the digital comparator low threshold to 40% of VIO.

3 (44_PERCENT): Set the digital comparator low threshold to 44% of VIO.

CMPHTH

Comparator High Threshold.

0 (48_PERCENT): Set the digital comparator high threshold to 48% of VIO.

1 (52_PERCENT): Set the digital comparator high threshold to 52% of VIO.

2 (56_PERCENT): Set the digital comparator high threshold to 56% of VIO.

3 (60_PERCENT): Set the digital comparator high threshold to 60% of VIO.

CALMD

Automatic Calibration Mode.

0 (UNTIL_PASS): Continue to calibrate until a passing condition occurs.

1 (UNTIL_FAIL): Continue to calibrate until a failing condition occurs.

CALPUMD

Automatic Calibration Pull-up Mode.

0 (FULL): Use full pull-up mode.

1 (SMALL): Use small pull-up mode.

2 (MEDIUM): Use medium pull-up mode.

3 (LARGE): Use large pull-up mode.

FPUPEN

Force Continuous Pull-up Enable.

0 (DISABLED): Pull-ups are enabled automatically by hardware.

1 (ENABLED): Always enable the pull-ups.

FPDNEN

Force Ground Input Enable.

0 (DISABLED): Disable input grounding.

1 (ENABLED): Enable input grounding. The IN0 and IN1 inputs are grounded.

PUVAL

Pull-up Value.

CALSEL

Automatic Calibration Input Select.

0 (IN0): Calibrate the IN0 input.

1 (IN1): Calibrate the IN1 input.

CALRF

Calibration Result Flag.

0 (NOT_SET): The automatic calibration operation did not succeed.

1 (SET): The automatic calibration operation succeeded.

CALBUSYF

Calibration Busy Flag.

0 (NOT_SET): A calibration operation is not in progress.

1 (SET): A calibration operation is in progress. Hardware will clear this flag when the operation completes.